[monitoring-plugins] Fix check_ups (broken since v3.0.0) (#2307)
GitHub
git at monitoring-plugins.org
Thu Jul 30 22:50:13 CEST 2026
Module: monitoring-plugins
Branch: master
Commit: 6bf0a042334c13ce64c00f05a1032987af2d6f36
Author: Louis Sautier <sautier.louis at gmail.com>
Committer: GitHub <noreply at github.com>
Date: Thu Jul 30 22:45:11 2026 +0200
URL: https://www.monitoring-plugins.org/repositories/monitoring-plugins/commit/?id=6bf0a042
Fix check_ups (broken since v3.0.0) (#2307)
* check_ups: fix inverted check for missing UPS name
The refactor in 29b1be07 dropped the negation when moving
validate_arguments() over to the config wrapper, so the check now fires
when a UPS name *is* given, making -u unusable.
* check_ups: actually report load, temperature, real power and status
Status, load, temperature and real power are only ever handed to
mp_add_subcheck_to_check() in their error branches, so unless the query
itself fails, they are computed and then thrown away - the plugin reports
a single battery line and nothing else. Load, temperature and real power
lose their perfdata too.
Also:
- sc_retrieve_status has no state at all, and an unset subcheck state
means UNKNOWN, which propagates to the whole check. Every run comes
back UNKNOWN regardless of the UPS.
- the real power branch writes its output into sc_temperature, dropping
the temperature text.
- mp_set_subcheck_default_state() returns the subcheck by value, but
the load one ignores the return, so the default never applies.
- the status string is built by appending to itself and starts out
NULL, giving "Status: (null)Online, Charging".
- stray spacing in the load label.
All of this came in with 29b1be07.
---
plugins/check_ups.c | 20 ++++++++++++++++----
1 file changed, 16 insertions(+), 4 deletions(-)
diff --git a/plugins/check_ups.c b/plugins/check_ups.c
index 525ecf24..ba58994e 100644
--- a/plugins/check_ups.c
+++ b/plugins/check_ups.c
@@ -94,10 +94,12 @@ int main(int argc, char **argv) {
mp_set_ok_summary(&overall, "UPS check is OK");
mp_subcheck sc_retrieve_status = mp_subcheck_init();
+ sc_retrieve_status = mp_set_subcheck_default_state(sc_retrieve_status, STATE_OK);
/* get the ups status if possible */
determine_status_result query_result = determine_status(config);
if (query_result.errorcode != OK) {
+ sc_retrieve_status = mp_set_subcheck_state(sc_retrieve_status, STATE_CRITICAL);
xasprintf(&sc_retrieve_status.output, "%s", "Failed to retrieve status from UPS tools");
mp_add_subcheck_to_check(&overall, sc_retrieve_status);
mp_exit(overall);
@@ -111,6 +113,7 @@ int main(int argc, char **argv) {
// Exit result
mp_subcheck sc_ups_status = mp_subcheck_init();
+ xasprintf(&sc_ups_status.output, "%s", "");
if (supported_options & UPS_STATUS) {
mp_state_enum ups_state_result = STATE_OK;
@@ -174,6 +177,7 @@ int main(int argc, char **argv) {
}
xasprintf(&sc_ups_status.output, "Status: %s", sc_ups_status.output);
sc_ups_status = mp_set_subcheck_state(sc_ups_status, ups_state_result);
+ mp_add_subcheck_to_check(&overall, sc_ups_status);
}
int res;
@@ -256,7 +260,7 @@ int main(int argc, char **argv) {
/* get the ups load percent if possible */
res = get_ups_variable("ups.load", temp_buffer, config);
mp_subcheck sc_load_percent = mp_subcheck_init();
- mp_set_subcheck_default_state(sc_load_percent, STATE_OK);
+ sc_load_percent = mp_set_subcheck_default_state(sc_load_percent, STATE_OK);
if (res == NOSUCHVAR) {
supported_options &= ~UPS_LOADPCT;
} else if (res != OK) {
@@ -268,7 +272,7 @@ int main(int argc, char **argv) {
supported_options |= UPS_LOADPCT;
double ups_load_percent = atof(temp_buffer);
- xasprintf(&sc_load_percent.output, "Load :%3.1f%% ", ups_load_percent);
+ xasprintf(&sc_load_percent.output, "Load: %3.1f%%", ups_load_percent);
mp_perfdata pd_load_percent = perfdata_init();
pd_load_percent.label = "load";
@@ -276,10 +280,12 @@ int main(int argc, char **argv) {
pd_load_percent.value = mp_create_pd_value(ups_load_percent);
pd_load_percent = mp_pd_set_thresholds(pd_load_percent, config.load_thresholds);
+ mp_add_perfdata_to_subcheck(&sc_load_percent, pd_load_percent);
sc_load_percent = mp_set_subcheck_state(sc_load_percent, mp_get_pd_status(pd_load_percent));
// if (config.check_crit && ups_load_percent >= config.critical_value) {
// } else if (config.check_warn && ups_load_percent >= config.warning_value) {
+ mp_add_subcheck_to_check(&overall, sc_load_percent);
}
/* get the ups temperature if possible */
@@ -312,10 +318,12 @@ int main(int argc, char **argv) {
pd_temperature = mp_set_pd_value(pd_temperature, ups_temperature);
pd_temperature = mp_pd_set_thresholds(pd_temperature, config.temperature_thresholds);
+ mp_add_perfdata_to_subcheck(&sc_temperature, pd_temperature);
sc_temperature = mp_set_subcheck_state(sc_temperature, mp_get_pd_status(pd_temperature));
// if (config.check_crit && ups_temperature >= config.critical_value) {
// } else if (config.check_warn && ups_temperature >= config.warning_value) {
+ mp_add_subcheck_to_check(&overall, sc_temperature);
}
/* get the ups real power if possible */
@@ -333,7 +341,7 @@ int main(int argc, char **argv) {
supported_options |= UPS_REALPOWER;
double ups_realpower = atof(temp_buffer);
- xasprintf(&sc_temperature.output, "Real power: %3.1fW ", ups_realpower);
+ xasprintf(&sc_real_power.output, "Real power: %3.1fW", ups_realpower);
mp_perfdata pd_real_power = perfdata_init();
pd_real_power.label = "realpower";
@@ -341,8 +349,12 @@ int main(int argc, char **argv) {
pd_real_power.uom = "W";
pd_real_power = mp_pd_set_thresholds(pd_real_power, config.real_power_thresholds);
+ mp_add_perfdata_to_subcheck(&sc_real_power, pd_real_power);
+ sc_real_power = mp_set_subcheck_state(sc_real_power, mp_get_pd_status(pd_real_power));
+
// if (config.check_crit && ups_realpower >= config.critical_value) {
// } else if (config.check_warn && ups_realpower >= config.warning_value) {
+ mp_add_subcheck_to_check(&overall, sc_real_power);
}
/* if the UPS does not support any options we are looking for, report an
@@ -653,7 +665,7 @@ check_ups_config_wrapper process_arguments(int argc, char **argv) {
}
check_ups_config_wrapper validate_arguments(check_ups_config_wrapper config_wrapper) {
- if (config_wrapper.config.ups_name) {
+ if (config_wrapper.config.ups_name == NULL) {
printf("%s\n", _("Error : no UPS indicated"));
config_wrapper.errorcode = ERROR;
}